EPA Section 609 certification is required for anyone paid, in any form, to work on a motor vehicle A/C system's refrigerant, including a top-off. You earn it by training with an EPA-approved program (ASE, MACS, ESCO, SkillCat and others) and passing its test, and no renewal is required today. The card also lets you buy refrigerant in containers the sales rules restrict. Below: 26 free practice questions with every answer explained, then the rules in plain words.
01Section 609 in brief
| Question | Short answer |
|---|---|
| Who needs it | Anyone who services or repairs vehicle A/C for consideration (cash, credit, goods or services), when the work involves the refrigerant. A top-off counts. |
| Who certifies | EPA-approved programs, not EPA itself: ASE, MACS, ESCO Institute, Mainstream Engineering, SkillCat, TEEX and others. |
| Renewal | None required today. EPA only reserves the right to require it in the future. |
| Buying refrigerant | Certified technicians can buy restricted MVAC refrigerant; anyone can buy R-134a or R-1234yf in self-sealing cans of 2 lb or less. |
| Shop duties | Approved recovery or recycling equipment, a one-time certification to EPA, and records kept on site for 3 years. |
| Never | Vent refrigerant (only CO2, R-744, is exempt), use an adapter to change a fitting, or leak-test an R-134a system with shop air. |
0226 EPA 609 practice questions
Tap an option to answer; your score, by topic, shows after the last question. 9 on rules and certification, 8 on refrigerants and fittings, 9 on recovery and equipment. Every explanation says why the right answer is right and why each wrong one is wrong, with the rule it comes from.
-
A mechanic recharges a neighbor's car A/C at home. The neighbor pays with a case of motor oil and a Saturday of help moving furniture, but no money. Does Section 609 require the mechanic to be certified?
- No, because no money changed hands
- Yes, because payment in goods or services counts as consideration
- Only if the work is done at a business address
- Only if the car uses CFC-12
Show the answer
B. Correct. Section 609 covers service done for consideration, which means being paid in any form: cash, credit, goods or services. Only work done for free is outside it, so the oil and the help count as payment.
Why not the others
A. Payment does not have to be money. The rule counts cash, credit, goods or services as consideration.
C. Where the work happens does not matter. The test is whether the person is paid in any form.
D. The certification requirement applies to service involving any MVAC refrigerant, including substitutes such as R-134a and R-1234yf, not only CFC-12.
ID 609-R-01 · 40 CFR 82.34(a)(2) · EPA 609 programs page · 40 CFR 82.32(g)
-
A quick-lube shop offers A/C top-offs only. It never opens or recovers a system; it just adds refrigerant to a low system. What do the Section 609 rules require of this shop?
- Nothing, because no refrigerant is removed
- Certified technicians, but no recovery equipment
- Approved recovery/recycling equipment and certified technicians
- Only a sign warning customers about refrigerant release
Show the answer
C. Correct. Charging a system with nothing else done is still "service involving refrigerant" under the rules. A shop that only tops off motor vehicle A/C must buy approved refrigerant recycling equipment and use certified technicians, like any other shop.
Why not the others
A. The rules define a top-off as service involving refrigerant, so a top-off-only shop is not exempt.
B. For shops that charge motor vehicle A/C systems, the top-off rule includes the requirement to buy approved refrigerant recycling equipment as well as using certified technicians.
D. The posted sign is a retail sales rule for small containers of class I or II refrigerant. It is not what a servicing shop must do.
ID 609-R-02 · 40 CFR 82.32(h) · 40 CFR 82.34(a)(1)
-
A customer with no Section 609 or 608 certificate asks a parts store for refrigerant to recharge a car's A/C. Which of these may the store legally sell to that customer?
- A 12 oz can of R-134a with a unique fitting and a self-sealing valve
- A 30 lb cylinder of R-134a
- A 10 lb cylinder of R-1234yf
- A 12 oz can of CFC-12
Show the answer
A. Correct. MVAC substitute refrigerant in a container of 2 lb or less, with a unique fitting and (for cans made since January 1, 2018) a self-sealing valve, is exempt from the sales restriction. That is the do-it-yourself can.
Why not the others
B. Since January 1, 2018, the sales restriction covers substitutes such as R-134a. A 30 lb cylinder is far above the 2 lb do-it-yourself limit.
C. R-1234yf is a restricted substitute too, and 10 lb is above the 2 lb exemption, so the buyer must be certified.
D. CFC-12 in containers under 20 lb may be sold only to technicians certified under Section 609 (or for resale). The small-can exemption is for substitutes, not CFC-12.
ID 609-R-03 · 40 CFR 82.34(b) · EPA MVAC requirements page · 40 CFR 82.154(c)(1)
-
A technician earned Section 609 certification in 2009 and has never had it revoked. What must they do under the current rules to keep servicing motor vehicle A/C systems?
- Recertify every five years
- Retake the test whenever a new refrigerant reaches the market
- Complete an annual refresher course
- Nothing: no recertification is required today
Show the answer
D. Correct. EPA only reserves the right to require recertification at some future date. Today a certificate stays valid unless EPA revokes it, for example after a technician fails to show proper recovery when asked.
Why not the others
A. There is no five-year cycle. The rules set no renewal period at all.
B. Programs must update their test material as technology changes, but technicians already certified are not required to retest.
C. No annual refresher is required by the Section 609 rules.
ID 609-R-04 · 40 CFR 82.40(d)
-
A technician has just passed the ASE A7 Heating and Air Conditioning test and wants to buy a 10 lb cylinder of R-1234yf. Does the A7 certification meet the Section 609 requirement?
- Yes, because A7 covers refrigerant recovery
- No: a separate 609 certification is needed, and ASE offers one
- Yes, as long as the A7 certification is current
- Only if the technician also holds ASE Master status
Show the answer
B. Correct. ASE says its HVAC certifications, A7 included, do not provide Section 609 credentials. ASE runs a separate Refrigerant Recovery and Recycling Review and Quiz program that does, and other EPA-approved programs such as MACS also certify technicians.
Why not the others
A. A7 does test recovery and recycling tasks, but ASE states that its A7, T7, H7 and S7 certifications do not satisfy EPA's Section 609 requirement.
C. Keeping A7 current does not change the answer. A7 is not a Section 609 certification.
D. Master status is earned from the A-series tests, none of which is a Section 609 certification.
ID 609-R-05 · ASE 2026 study guide (A7) · 40 CFR 82.154(c)(1) · EPA 608/609 overlap page
-
A shop owns approved refrigerant recycling equipment. For how long, and where, must it keep records showing that everyone who operates the equipment is certified?
- At least three years, kept at the shop
- One year, filed with the EPA Regional Office
- Five years, at any company location
- Only while the technician works there
Show the answer
A. Correct. Records must be kept for a minimum of three years, and businesses that service motor vehicle A/C for pay must keep them on site, where an EPA representative may ask to see them.
Why not the others
B. The records stay at the shop, not with EPA, and one year is too short: the minimum is three years.
C. The rule is three years, and the records are kept on site at the business that does the servicing.
D. The rule sets a fixed minimum of three years, not the length of a technician's employment.
ID 609-R-06 · 40 CFR 82.42(b)(2) · EPA MVAC requirements page
-
A new repair shop buys an approved recovery/recycling machine and starts doing A/C work for customers. What must it send to EPA about the equipment?
- A yearly report of the refrigerant recovered
- A monthly log of every vehicle serviced
- A one-time certification statement to its EPA Regional Office
- Nothing, because the equipment maker registers it
Show the answer
C. Correct. The shop certifies to EPA once, in a statement signed by the owner or a responsible officer, giving the equipment details and confirming that everyone authorized to use it is certified. EPA calls this a one-time requirement.
Why not the others
A. There is no yearly recovery report for MVAC shops under these rules.
B. No vehicle log has to be sent to EPA. The shop keeps its certification records on site.
D. The equipment maker has its own duties, but the shop must still send its own certification to EPA.
ID 609-R-07 · 40 CFR 82.42(a)(1) · EPA MVAC requirements page
-
A technician repairs the air conditioning on farm tractors and combines, which EPA treats as MVAC-like appliances. Which certification may the technician hold for this work?
- Section 609 only
- Section 608 Type I only
- None, because farm equipment is off-road
- Either Section 609 or Section 608 Type II; EPA suggests 609
Show the answer
D. Correct. EPA says technicians servicing MVAC-like appliances, such as farm equipment and other non-road vehicles, may be certified under either program, and it recommends that they consider Section 609.
Why not the others
A. Section 609 is one choice, but not the only one: Section 608 Type II also qualifies for MVAC-like appliances.
B. Type I covers small appliances. For MVAC-like appliances the choices are Section 609 or Section 608 Type II.
C. Technicians servicing MVAC-like appliances such as farm equipment must be certified.
ID 609-R-08 · 40 CFR 82.34(a)(3) · EPA 608/609 overlap page
-
Which of these must every EPA-approved Section 609 certification program do?
- Give the test only at an EPA office
- Verify each test-taker's identity and give each certified technician a unique number
- Offer the test in English only
- Include a hands-on recovery demonstration in the test
Show the answer
B. Correct. Approved programs must use a grader who receives no benefit from the outcome, take steps so each technician completes the test honestly, verify identity, and give each certified technician individual proof of certification with a unique number.
Why not the others
A. The programs, not EPA, give the tests. EPA approves the programs and sets the standards they must meet.
C. Programs are encouraged to offer tests in other languages or allow a translator; if a translator is used, the certificate must say so.
D. Training can be self-study, on-the-job or on-site. A hands-on test is not required, although EPA can later ask a technician to demonstrate proper recovery at the shop.
ID 609-R-09 · 40 CFR 82.40(a)(3) · 40 CFR 82.40(a)(4)
-
Which refrigerant may be released to the air during motor vehicle A/C service without breaking the venting prohibition?
- R-1234yf, because its global warming potential is low
- R-134a, because it does not deplete ozone
- Carbon dioxide (R-744)
- None of them may ever be released
Show the answer
C. Correct. CO2 is the only MVAC refrigerant exempt from the venting prohibition. EPA notes that it is not exempt from the Section 609 requirements, so technicians servicing CO2 systems still need certification.
Why not the others
A. R-1234yf is not exempt. Knowingly venting refrigerant, substitutes included, is prohibited.
B. R-134a does not deplete ozone, but it is still covered by the venting prohibition.
D. There is one exemption: carbon dioxide may be vented.
ID 609-F-01 · 40 CFR 82.32(e)(2) · 40 CFR 82.154(a)(1) · 40 CFR 82.154(a)(1)(i)
-
A technician needs to recover refrigerant from an R-1234yf system, but the only hoses at hand have R-134a couplers. Under EPA's fitting rules, may the technician use an adapter to connect them?
- Yes, if the adapter meets an SAE standard
- No: each refrigerant has its own fittings, and adapters may not convert them
- Yes, for recovery only, but not for charging
- Yes, if the system label is changed afterward
Show the answer
B. Correct. Every MVAC refrigerant approved under SNAP has a unique set of fittings so refrigerants are not mixed by accident, and EPA states that an adapter may not be used to convert a fitting. Use equipment made for R-1234yf.
Why not the others
A. EPA's rule has no exception for SAE-standard adapters: an adapter may not be used to convert a fitting.
C. The adapter prohibition is not limited to charging. Unique fittings also keep the wrong refrigerant out of recovery equipment.
D. Relabeling does not make an adapter acceptable. The fittings exist to prevent mixing in the first place.
ID 609-F-02 · EPA fittings page
-
Under EPA's fitting specifications, which refrigerant's cylinders and small cans use a left-hand thread?
- HFC-134a
- CFC-12
- HFC-152a
- HFO-1234yf
Show the answer
D. Correct. EPA lists an 8/16-16 left-hand thread for HFO-1234yf cylinders and small cans, which keeps them from fitting R-134a equipment.
Why not the others
A. HFC-134a cans and cylinders use a right-hand Acme thread; its vehicle service ports are quick-connect couplers.
B. CFC-12 containers use a right-hand 7/16-20 thread.
C. EPA's table lists quick-connect service ports for HFC-152a and gives no left-hand container thread.
ID 609-F-03 · EPA fittings page
-
A refrigerant container carries a sky blue label under EPA's MVAC label colors. Which refrigerant is it?
- HFC-134a
- CFC-12
- HFO-1234yf
- Carbon dioxide (R-744)
Show the answer
A. Correct. EPA's label color for HFC-134a is sky blue; CFC-12 is white.
Why not the others
B. CFC-12's assigned label color is white.
C. EPA assigns no label color to HFO-1234yf. It is labeled to SAE J639 instead.
D. EPA assigns no label color to R-744; like R-1234yf it follows SAE J639 labeling.
ID 609-F-04 · EPA fittings page
-
SAE J639 requires a warning label on vehicles whose A/C uses R-1234yf. Which property of R-1234yf is that label about?
- R-1234yf is highly toxic when it leaks
- R-1234yf is mildly flammable (ASHRAE class A2L)
- R-1234yf depletes the ozone layer
- R-1234yf systems run at much higher pressure than CO2 systems
Show the answer
B. Correct. EPA describes HFO-1234yf as mildly flammable (ASHRAE A2L) but able to be used safely under its SNAP use conditions, which require the SAE J639 safety features, including a flammable-refrigerant warning label, a high-pressure compressor cutoff switch, pressure relief devices and unique fittings.
Why not the others
A. The warning is about flammability, not toxicity.
C. R-1234yf is an HFO, one of the non-ozone-depleting refrigerants. The label is about flammability.
D. Pressure is not the reason for the label. CO2 systems are the high-pressure ones.
ID 609-F-05 · EPA refrigerants page
-
A customer asks whether a new light-duty vehicle built for model year 2026 can come with an R-134a A/C system. What is correct?
- No: from model year 2025, new light-duty vehicles may not use HFCs with a GWP of 150 or more, such as R-134a, but existing vehicles can still be serviced with R-134a
- Yes, R-134a is still acceptable in all new vehicles
- Yes, but only if the system has CFC-12 fittings
- No, and every existing R-134a vehicle must now be converted
Show the answer
A. Correct. EPA's 2023 Technology Transitions rule restricts HFCs with a global warming potential of 150 or more, such as R-134a, in newly manufactured light-duty vehicles from model year 2025. Existing vehicles can still be serviced with R-134a.
Why not the others
B. Not for new light-duty vehicles: the Technology Transitions rule restricts R-134a in them from model year 2025.
C. CFC-12 fittings have nothing to do with it; each refrigerant keeps its own unique fittings.
D. The rule applies to newly manufactured vehicles. EPA says existing vehicles can still be serviced with R-134a.
ID 609-F-06 · EPA refrigerants page
-
A 1993 car still holds its original CFC-12. Compared with releasing R-134a, what makes releasing CFC-12 a particular concern?
- CFC-12 is flammable
- CFC-12 is the only refrigerant covered by the venting prohibition
- CFC-12 depletes the stratospheric ozone layer; R-134a does not
- CFC-12 can no longer be recovered with approved equipment
Show the answer
C. Correct. CFC-12 is an ozone-depleting CFC, and the Section 609 test must cover ozone depletion and the effects of releasing refrigerant. EPA describes HFCs such as R-134a as non-ozone-depleting, though they are still covered by the venting and sales rules.
Why not the others
A. Flammability is a concern with R-1234yf (A2L), not CFC-12.
B. Knowingly venting is prohibited for substitutes such as R-134a too; only CO2 is exempt.
D. Approved CFC-12 recovery and recycling equipment exists, and the rules set standards for it.
ID 609-F-07 · 40 CFR 82.32(e)(2) · 40 CFR 82.154(a)(1) · 40 CFR 82.40(a)(2)
-
A technician certified only under Section 609 wants to buy a 30 lb cylinder of HCFC-22. What applies?
- It is allowed, because the 20 lb limit applies only to smaller containers
- It is allowed if the HCFC-22 is for MVAC-like appliances
- It is allowed with a written statement that it is for vehicle use
- It is not allowed: 609 technicians cannot buy HCFC-22 in any size container
Show the answer
D. Correct. EPA states that Section 609 technicians cannot purchase HCFC-22 in any size container. Section 609 certification is for motor vehicle A/C refrigerants.
Why not the others
A. The 20 lb threshold is the sales rule for class I and II refrigerants such as CFC-12. For HCFC-22, EPA states that 609 technicians cannot buy it in any size.
B. EPA's statement about HCFC-22 has no MVAC-like exception.
C. A written statement is used only when containers are bought for resale. It does not let a 609 technician buy HCFC-22.
ID 609-F-08 · EPA 608/609 overlap page
-
Following the recommended recovery procedure, a technician runs the recovery unit until the system reaches a vacuum, then shuts it off. Five minutes later, the gauge shows positive pressure in the system. What should the technician do?
- Recover again, and repeat until the vacuum holds steady for 2 minutes
- Start the repair, since the pressure rise is normal
- Open a service port to let the small amount left escape
- Add nitrogen to push the rest into the recovery tank
Show the answer
A. Correct. Pressure coming back means refrigerant is still in the system. The recommended procedure is to recover again and repeat until the system's vacuum stays stable for 2 minutes before opening it.
Why not the others
B. Opening a system that still holds refrigerant releases it. The pressure rise shows recovery is not finished.
C. That is venting, which is prohibited. The remaining refrigerant must be recovered.
D. The procedure does not call for nitrogen. It calls for running the recovery unit again until the vacuum holds.
ID 609-E-01 · 40 CFR 82 subpart B appendix A
-
What is the most a refrigerant storage container may be filled with liquid, as the recovery equipment standards in the Section 609 rules set it?
- 60 percent of its rated volume
- 80 percent of its rated volume at 70°F (21°C)
- 95 percent of its rated volume
- 100 percent, as long as it is kept below 120°F
Show the answer
B. Correct. Recovery equipment must have overfill protection so the container's liquid fill does not exceed 80 percent of its rated volume at 70°F, per DOT rules. The space left lets the liquid expand as it warms.
Why not the others
A. 60 percent is below the limit. The standards allow filling to 80 percent.
C. 95 percent leaves too little room for the liquid to expand as temperature rises; the limit is 80 percent.
D. A full container has no room for expansion and can be overpressurized. The limit is 80 percent.
ID 609-E-02 · 40 CFR 82 subpart B appendix C
-
Under the equipment standards in the Section 609 rules, what does a refrigerant container with a gray body and a yellow top hold?
- New refrigerant ready to charge
- Recycled refrigerant that meets the purity standard
- Used refrigerant that must be processed before reuse
- Dry nitrogen for flushing
Show the answer
C. Correct. Under the equipment standards, a gray container with a yellow top holds used refrigerant, marked in black "DIRTY ... DO NOT USE, MUST BE PROCESSED". Contaminated R-134a uses a blue container with a yellow top.
Why not the others
A. Gray with a yellow top marks used refrigerant, not new refrigerant.
B. Gray with a yellow top is the code for used refrigerant that has not been processed yet, not for recycled refrigerant.
D. The gray body and yellow top identify used refrigerant, not nitrogen.
ID 609-E-03 · 40 CFR 82 subpart B appendix B
-
A technician recovers R-134a from a car with an approved recovery/recycling machine to replace a leaking hose. After the repair, what must happen before that same refrigerant goes back into the same car?
- It must be recycled first, even though it is going back into the same car
- Nothing, because it is the car's own refrigerant
- It must be sent off site to a reclaimer
- It must be released and replaced with new refrigerant
Show the answer
A. Correct. With recovery/recycling equipment, properly using it means recycling the refrigerant before it is returned to a vehicle, including the vehicle it came from.
Why not the others
B. Coming from the same car is not an exception. The rule says recycle before returning it, including to the same vehicle.
C. Off-site reclamation is one route for recover-only equipment. A recovery/recycling machine recycles on site.
D. Releasing refrigerant is prohibited venting.
ID 609-E-04 · 40 CFR 82.32(e)(1)
-
Which of these must never be done when leak-testing an R-134a system, according to the R-134a equipment standard in the Section 609 rules?
- Use an electronic leak detector
- Look for UV dye at the joints
- Check the recovered weight against the label charge
- Pressurize the system with shop air mixed with R-134a
Show the answer
D. Correct. The standard says that under no circumstances should equipment be pressure- or leak-tested with air/R-134a mixtures, and not to use compressed (shop) air in systems containing R-134a.
Why not the others
A. Electronic leak detection is a normal method and is not prohibited.
B. Dye leak detection is not prohibited by the standard.
C. Comparing recovered weight with the label charge is a way to judge how much was lost, not a prohibited test.
ID 609-E-05 · 40 CFR 82 subpart B appendix C
-
A shop is buying a machine that recovers, recycles and recharges R-1234yf. Which SAE standard must the machine meet under the Section 609 rules?
- SAE J2788
- SAE J2843
- SAE J2810
- SAE J1771
Show the answer
B. Correct. Equipment that recovers and recycles HFO-1234yf and recharges systems with it must meet SAE J2843. A machine for both R-1234yf and R-134a must meet SAE J3030.
Why not the others
A. J2788 is the standard for R-134a recover/recycle(/recharge) equipment.
C. J2810 covers R-134a recovery-only equipment.
D. J1771 is the standard for refrigerant identifiers, not recover/recycle/recharge machines.
ID 609-E-06 · 40 CFR 82.36(a)(4)
-
The equipment standards require shutoff devices at the system end of the service hoses. What is their purpose?
- To let the technician vent the hoses quickly
- To hold the system at a vacuum during evacuation
- To keep air out of the equipment on connection and cut refrigerant release on disconnection
- To meter the charge into the system
Show the answer
C. Correct. Shutoffs at the connection point minimize noncondensable gases (air) getting into the recovery equipment and the refrigerant released when the hoses are disconnected. For CFC-12 they must be within 12 inches of the service end.
Why not the others
A. Venting is prohibited. The shutoffs exist to keep refrigerant in the hoses.
B. Holding a vacuum is not the purpose the standards give for hose shutoffs.
D. Charge amount is measured by the machine or a scale, not by the hose shutoffs.
ID 609-E-07 · 40 CFR 82 subpart B appendix A
-
After recovery, the machine reports that 1.5 oz of oil was separated from the recovered refrigerant. What should the technician do with this information when recharging?
- Pour the separated oil back into the system
- Add no oil, since the amount is small
- Add double the amount to be safe
- Add the same amount of new oil of the correct type
Show the answer
D. Correct. The equipment separates and measures the oil so the technician knows how much to replace, and the standard says to use only new lubricant to replace it and to discard the used oil under the applicable rules.
Why not the others
A. Separated oil is used oil; the standard says to replace it with new lubricant and discard the used oil properly.
B. The machine measures the oil so the technician can replace what came out. Skipping it leaves the system short.
C. Adding more than was removed overfills the system with oil. Replace the measured amount.
ID 609-E-08 · 40 CFR 82 subpart B appendix C
-
An R-134a recovery/recycling machine warns that its filter is close to the limit of its moisture capacity. What does the equipment standard expect the technician to do?
- Keep using it until the filter is fully saturated
- Replace the filter (desiccant) before it saturates
- Vent some refrigerant to lower the moisture
- Add extra oil to absorb the water
Show the answer
B. Correct. Under SAE J2788 the machine's desiccant must be replaced before it saturates with moisture. The machine has to warn the user in time, and the maker must build in a lockout when the end of filter life is reached.
Why not the others
A. The standard requires the user to be alerted so the filter is replaced before full saturation, and the machine locks out at the end of filter life.
C. Venting is prohibited, and it would not dry the refrigerant.
D. Oil does not dry refrigerant. The filter's desiccant does, which is why it must be replaced.
ID 609-E-09 · 40 CFR 82 subpart B appendix C
03The 609 card vs ASE A7
The 609 card is the legal minimum; ASE A7 shows you can fix the system. Section 609 proves you know the refrigerant rules: recovery, recycling, the sales restriction and what never to vent. ASE's A7 Heating and Air Conditioning test asks whether you can diagnose and repair the whole system: pressures and temperatures, components, controls and the engine cooling system.
The two overlap. A7's task list includes identifying the refrigerant and recovering it, verifying certified equipment, recycling, labeling and storing refrigerant and testing cylinders for noncondensable gases. But ASE says its A7 certification does not satisfy Section 609, so a technician doing A/C work for pay needs the 609 card either way.
Here is how A7 asks about the refrigerant work you just practiced: three questions from our A7 bank, a level deeper than the 609 rules.
-
Before recovery, a refrigerant identifier sampling a vehicle labeled R-134a reads: R-134a 99.2%, R-12 0.0%, R-22 0.8%, hydrocarbons 0.0%, air 9%. Its instructions say a sample passes when one refrigerant makes up 98% or more of the refrigerant measured and the air, reported separately, is 10% or less. What does this result mean?
- It fails on air and goes to a contaminated tank
- It passes and can go into the R-134a machine
- It fails on R-22 and goes to a contaminated tank
- It passes once air is bled off at the service port
Show the answer
B. Correct. 99.2% R-134a clears the 98% pass mark and 9% air is within the 10% limit, so the refrigerant can be recovered with the R-134a machine, which separates air from the refrigerant as it recycles. The high air reading is still worth noting, since air in a system raises head pressure.
Why not the others
A. The 9% air is under the instructions' 10% limit, so air does not fail this sample; the recycling machine purges the air it takes in.
C. 0.8% R-22 leaves the sample at 99.2% R-134a, above the 98% pass mark, so it is not treated as contaminated.
D. Opening the service port releases refrigerant along with the air, and it is not needed: the machine separates air during recycling.
ID A7-A-014 · Task A7-A-5 (ASE task list)
-
A tank of recycled R-134a has stood for 12 hours at 65°F or above, out of direct sun. The air temperature 4 in. from the tank reads 75°F, and the tank pressure reads 96 psi. The machine maker's chart allows no more than 81 psi at 75°F for recycled R-134a. What should the technician do first?
- Vent a little vapor from the top into the recycler and recheck.
- Use the refrigerant, since a reading above the chart means a full tank.
- Recycle the entire contents of the tank before any venting is tried.
- Draw liquid from the bottom into the recycler and recheck.
Show the answer
A. Correct. A pressure above the chart value means noncondensable gas, mainly air, is in the tank, and it collects in the vapor space above the liquid. Venting a little vapor from the top into the recycling equipment removes it; if the pressure still exceeds the chart, the whole contents are recycled.
Why not the others
B. Tank pressure follows temperature, not how full the tank is, as long as liquid is present. A reading 15 psi over the chart at a stable 75°F points to air in the tank, which is vented from the top into the recycling equipment before the refrigerant is used.
C. Recycling the whole tank is the step taken if the pressure is still too high after venting. The first step is to vent a small amount of vapor from the top of the tank, where the air collects, into the recycling equipment and recheck.
D. Air does not dissolve in the liquid; it gathers in the vapor space at the top of the tank. Drawing liquid from the bottom leaves the air behind, so vapor is vented from the top into the recycling equipment instead.
ID A7-A-046 · Task A7-A-18 (ASE task list) · 40 CFR 82 · SAE J1989
-
Before recovering an R-134a system that cools poorly, a technician wants to know whether it was low on refrigerant. Technician A says comparing the weight the machine recovers with the label charge shows how much was missing. Technician B says a static pressure that matches the pressure-temperature chart at the ambient temperature shows the system is fully charged. Who is right?
- A only
- B only
- Both A and B
- Neither A nor B
Show the answer
A. Correct. Only Technician A is right. Recovery weighs what comes out, so a recovered weight well below the label charge measures what leaked away. Technician B is wrong: while any liquid remains, static pressure equals the refrigerant's saturation pressure at that temperature, so a nearly empty system can read the same as a full one.
Why not the others
B. Technician B is wrong: static pressure follows temperature, not the amount of refrigerant, as long as any liquid is left. Technician A is right that the recovered weight shows the shortfall.
C. Technician A is right, but Technician B is not: a system with only a little liquid left shows the same static pressure as a full one at the same temperature.
D. Technician B is wrong, but Technician A is right: weighing the recovered charge against the label is how the missing amount is found.
ID A7-A-016 · Task A7-A-5 (ASE task list)
04Who needs Section 609 certification
- Anyone paid to work on vehicle A/C refrigerant. "For consideration" means payment of any kind: cash, credit, goods or services. Only work done completely free is outside it.
- Top-off shops too. Charging a system with nothing else done is still "service involving refrigerant", so a shop that only tops off needs approved recycling equipment and certified technicians.
- MVAC-like appliances (farm equipment and other non-road vehicles): technicians may hold Section 609 or Section 608 Type II, and EPA suggests they consider 609.
- CO2 (R-744) systems are not exempt from Section 609, even though CO2 is the one refrigerant that may be vented.
The rules cover motor vehicles: self-propelled vehicles built to carry people or property on streets and highways, from cars to heavy trucks. They do not cover sealed cargo refrigeration units or HCFC-22 bus air conditioning.
05How to get 609 certified
- Pick an EPA-approved program. EPA's list has 23 programs open to the public, including ASE, MACS (Mobile Air Climate Systems Association), ESCO Institute, Mainstream Engineering, SkillCat and Texas A&M's TEEX. Programs set their own fees and test format, so compare them.
- Study the training material. Training can be self-study, on-the-job or on-site with an instructor. The test must cover the service and recovery standards, the environmental effects of releasing refrigerant and ozone depletion, new refrigerants, and the Section 609 rules.
- Pass the test. The grader must gain nothing from your result, your identity must be verified, and the test must be completed honestly. Programs may offer other languages or allow a translator (the certificate then says so).
- Keep your proof. You get a certificate or wallet card with a unique number. Your employer keeps proof of your certification on site, and parts stores ask to see it when you buy restricted refrigerant.
Once certified, you are done: no renewal is required today. EPA can ask a technician to show proper recovery at the shop, and a technician who fails can have the certificate revoked.
06Buying refrigerant
| Refrigerant and container | Who may buy it |
|---|---|
| CFC-12, container under 20 lb | Only 609-certified technicians (or a buyer for resale, with a written statement). Stores selling it must post a sign saying so. |
| R-134a or R-1234yf, larger than 2 lb | Certified technicians (609, or 608) or a business employing one. Restricted since January 1, 2018. |
| R-134a or R-1234yf, can of 2 lb or less | Anyone, if the can has a unique fitting and (made since January 1, 2018) a self-sealing valve that closes when not dispensing. |
| HCFC-22 | Not 609 technicians, in any size container. |
07Refrigerants, fittings and labels
| Refrigerant | Vehicle service ports | Cans and cylinders | Label |
|---|---|---|---|
| CFC-12 (R-12) | Threaded: high 6/16-24, low 7/16-20 | 7/16-20, right-hand | White |
| HFC-134a (R-134a) | Quick-connect couplers | 8/16-16 Acme, right-hand | Sky blue |
| HFO-1234yf (R-1234yf) | Quick-connect: high 17 mm, low 14 mm | 8/16-16, left-hand | SAE J639 (flammable refrigerant warning) |
| CO2 (R-744) | Quick-connect: high 18.1 mm, low 16.6 mm (provisional) | Cylinders only so far | SAE J639 |
- Every refrigerant has its own fittings so refrigerants are not mixed by accident, and an adapter may not be used to convert a fitting.
- R-1234yf is mildly flammable (ASHRAE A2L), which is why its systems carry a flammable refrigerant warning label.
- R-134a is being phased out of new cars. From model year 2025, new light-duty vehicles may not use HFCs with a global warming potential of 150 or more, such as R-134a, but existing R-134a vehicles can still be serviced with it.
- CFC-12 depletes the ozone layer; R-134a and R-1234yf do not, but the venting and sales rules cover them too.
08Recovery and recycling: what the rules expect
- Use approved equipment, certified to the standard for the refrigerant: SAE J2788 for R-134a recover/recycle/recharge machines, J2810 for R-134a recover-only, J2843 for R-1234yf, J3030 for machines that handle both, J2851 for contaminated refrigerant. Identifiers meet SAE J1771.
- Recover before you open the system. Run recovery until the system is in a vacuum, shut off, and check after at least 5 minutes. If pressure returns, recover again, until the vacuum holds steady for 2 minutes.
- Close the hose shutoffs before disconnecting. They keep air out of the machine and refrigerant in the hoses.
- Recycle before it goes back in, even into the car it came from. Recover-only refrigerant is recycled on site or sent off for reclamation, and reclaimed refrigerant must meet the ARI 700 purity standard.
- Replace the oil the machine separated with the same amount of new oil, and discard the used oil properly.
- Fill storage containers to 80% at most (of rated volume at 70°F). Used refrigerant goes in gray containers with yellow tops; contaminated R-134a in blue containers with yellow tops.
- Never vent refrigerant, and never pressure- or leak-test an R-134a system with shop air or an air/R-134a mix.
09Free EPA 609 study sheet
The 609 rules on two pages
Everything above in printable form: who needs certification, the refrigerant sales rules, the fittings and label table, the equipment standards and the recovery steps. Free, as a PDF.
10Questions people ask
What is EPA 609 certification?
Who needs Section 609 certification?
How do I get EPA 609 certified?
Does EPA 609 certification expire?
Can I buy R-134a or R-1234yf without a 609 card?
Does ASE A7 count as Section 609 certification?
Are these the real EPA 609 test questions?
Is ToolboxPrep affiliated with the EPA?
11Sources
- 40 CFR part 82, subpart B (Servicing of Motor Vehicle Air Conditioners): definitions, prohibitions, approved equipment, technician certification, shop certification and records, and the equipment standards in its appendices
- 40 CFR 82.154 (prohibitions under Section 608): the venting prohibition, the refrigerant sales restriction and the small-can exemption
- EPA: Section 609 technician training and certification programs: who must be certified and the list of approved programs
- EPA: Regulatory requirements for MVAC system servicing: the CO2 venting exemption, the one-time shop certification and the 3-year records
- EPA: Unique fittings and label colors: fittings for each refrigerant, the adapter rule and label colors
- EPA: Acceptable refrigerants and their impacts: R-1234yf, R-744 and HFC-152a use conditions and the model year 2025 limit on R-134a
- EPA: Overlap between Section 608 and Section 609: MVAC-like appliances, HCFC-22 and the 2018 extension of the sales restriction
Facts checked November 1, 2026. Certification programs set their own fees and test formats; the program you choose is the final word on those. Found something out of date? Tell us.
12Practice next
ToolboxPrep is an independent study site, not affiliated with or endorsed by the U.S. Environmental Protection Agency (EPA), ASE or any Section 609 certification program. These practice questions are original and are not a certification: only an EPA-approved program can certify you.